Service Charges and Ordering
Service Charges
Maximum Number of Samples per Plate | Sample Number | HKU Academic Research per Sample | Other Academic Research per Sample | |||
DNF-474 HS NGS Fragment Kit (1 – 6,000 bp) | 95 | 1 – 47 | HK$ 50 | HK$ 55 | ||
48 – 95 | HK$ 45 | HK$ 50 | ||||
DNF-472 HS RNA Kit (15 nt) | 88 | 1 – 88 | HK$ 65 | HK$ 75 |
Effective 1-May-2024
Other assays are also available upon request, please contact platform specialists. For the complete list of assays available from Agilent, please visit Agilent Fragment Analyzer website.
For commercial clients, please enquire.
*IMPORTANT*: To qualify for HKU pricing, the investigator must be a regular employee of HKU AND payment must be made from an internal HKU financial account that qualifies for internal transfer. An overhead charge is required for all incoming external funding.
Service Ordering
Please submit service request through iLab.
Workflow
Sample Preparation and Submission
Sample Preparation and Submission Guidelines
(1) Prepare samples according to the sensitivity range provided in the table below and submit them in the designated vessel types stated below. Please label the tubes/strips/plates clearly and provide the full names of the sample in the sample submission form.
Sample Quantity | Vessel Type | Remarks |
≤ 8 | 1.5 mL tubes | |
9 – 32 | 8-well strips with caps | |
> 32 | 96-well plate | 1. Arrange samples by column, i.e. fill down A1 – H1 -> A2 – H2 and so on. |
2. For DNF-474 users (DNA samples), leave well H12 empty for ladder. | ||
3. For DNF-472 users (RNA samples), leave last column (A12 – H12) empty for ladder. |
(2) Based on our in-house experience, it is advisable to aim for a concentration around the midpoint of the sensitivity range, as this tends to yield the best results. Concentrations towards the lower end of the range may not provide reliable data.
Fragment Analyzer Assay | Sizing Range | Recommended Concentration Range | Minimum Sample Volume | Maximum number of samples per plate |
DNF-474 HS NGS Fragment Kit (1 – 6,000 bp) | 100 – 6,000 bp | Sharp Peak*: 0.25 – 0.5 ng/μL | 5 μL | 95 |
Broad Peak**: 1.25 – 2.5 ng/μL | ||||
DNF-472 HS RNA Kit (15 nt) | 200 – 6,000 nt | Total RNA: 2.5 – 5 ng/μL | 5 μL | 88 |
*e.g. amplicon
**e.g. NGS library
If plate(s) are being used, record plate ID on BOTH the submission form and the plate(s).
(4) Submit service request through iLab. Unless otherwise specified, a smear analysis between 200 bp and 1,000 bp would be included in the report for all DNA assays.
(5) Submit completed Fragment Analyzer sample submission form as attachment on iLab.
(6) Contact platform specialist for sample submission appointment.
(7) Bring the samples to the Fragment Analyzer Platform at the Core.
Special notes for Illumina Sequencing (Next Generation Sequencing) users
Please contact our Illumina platform specialists (nextgenseq.cpos@hku.hk) prior to submitting your samples to the Core.
*IMPORTANT*: It is not recommended to rely on the concentration indicated on the Fragment Analyzer report for NGS library quantity check and NGS sequencing preparation. We advise using qPCR for accurate measurement of NGS library concentration.
For more details about submission requirements for Illumina Sequencing, kindly visit the Illumina Sequencing Sample Requirements and Submission webpage.
If your samples do not meet above requirements, please feel free to reach out to us (fragmentanalyzer.cpos@hku.hk / 2831-5479) for assistance.
Data Collection
Processing Time
The expected turnaround time is usually 1 – 3 working days.
Data Delivery
Results will be delivered in PDF format via our Online Data Delivery System (ODDS).
Unless otherwise specified, a smear analysis between 200 bp and 1,000 bp would be included in the report for all DNA assays.
Terms of Service
Leftover Samples
Leftover samples will be kept for one week after the delivery of results.
Users are welcome to collect any leftover samples during this period, after which the samples will be discarded without further notice.
Please contact our platform specialist for sample pick-up arrangement.
Contact
Mr YIU, Francis